+81 3 6435 7474

Integrated distance measuring system Type AMSD 4B

Easy to change the read head = easy to install whilst at the same time offering high quality and precision

Easy to change the read head = easy to install whilst at the same time offering high quality and precision

Request for quote

To receive a quote please fill in this form below. One of our sales representatives is glad to help you.

Integrated measuring system for distance 
measurement type AMSD 4B
Integrated measuring system for distance measurement type AMSD 4B

The MONORAIL AMSD 4B is an integrated magneto-resistive measuring system for distance measurement based on the MONORAIL BM profile guideway with an incremental, digital interface. The AMSA 4B is the starting point for this product. The section rails are thus identical and are compatible with both AMSA 4B and AMSD 4B.

The AMSD 4B version has an incremental, digital interface and a range of reading head options that permit different resolutions and allow the system to be adapted to control systems with different input frequencies.


Frequently Asked Questions about the AMSD System from SCHNEEBERGER

After installing an AMSD system, the absolute position is available immediately after a reference run once the system is powered on.

When replacing read heads, slight deviations of up to a few tenths of a millimeter may occur. If more precise values are needed, adjustments to the control parameters should be made.

The AMSD system outputs the configured maximum frequency even when stationary. The control receiver must always be capable of receiving this maximum frequency.

Precise alignment of the read head is not necessary. It is sufficient to securely fasten it with the screws provided.

The periodic deviation is less than 0.8 µm, ensuring high precision.

The scale of the AMSD system is protected within the rail. External fields are shielded by the construction of the rail and surrounding components, so no interference occurs.

It is recommended to mount the scale on the side opposite the linear motor to prevent magnetic fluxes from chips or tools from affecting the scale.

Magnetic lifting tools should not be used when installing AMSD rails to avoid residual magnetism in the rail.

All components from the MONORAIL MR and MONORAIL BM series are compatible with the AMSD system. However, it should be noted that sheet metal wipers are not included in the standard program.

Is a calibration required after installing an AMSD system? //

After installing an AMSD system, the absolute position is available immediately after a reference run once the system is powered on.


Does the exact absolute position need to be reset when replacing components in the AMSD system? //

When replacing read heads, slight deviations of up to a few tenths of a millimeter may occur. If more precise values are needed, adjustments to the control parameters should be made.


How does the output frequency relate to the travel speed in the AMSD system? //

The AMSD system outputs the configured maximum frequency even when stationary. The control receiver must always be capable of receiving this maximum frequency.


Does the read head need to be aligned when installing the AMSD system? //

Precise alignment of the read head is not necessary. It is sufficient to securely fasten it with the screws provided.


How does the signal period of 200 µm affect the measurement accuracy of the AMSD system? //

The periodic deviation is less than 0.8 µm, ensuring high precision.


Can external fields from motors and rotary tables affect the scale of the AMSD system? //

The scale of the AMSD system is protected within the rail. External fields are shielded by the construction of the rail and surrounding components, so no interference occurs.


What should be considered when using linear motors in the AMSD system? //

It is recommended to mount the scale on the side opposite the linear motor to prevent magnetic fluxes from chips or tools from affecting the scale.


What are the installation requirements for the AMSD system? //

Magnetic lifting tools should not be used when installing AMSD rails to avoid residual magnetism in the rail.


What accessories are compatible with the AMSD system? //

All components from the MONORAIL MR and MONORAIL BM series are compatible with the AMSD system. However, it should be noted that sheet metal wipers are not included in the standard program.


Integrated digital and analog distance measuring system (with rollers or balls)

Digital and analog measuring systems enable precise linear motion and maintain the tightest tolerances

 Type AMSA 3BType AMSD 3BType AMSA 4BType AMSD 4BType AMSABS 3BType AMSABS 4BType AMSA 3LType MINISCALE PLUSType MINISLIDE MSQscale
Type AMSA 3BType AMSD 3B Type AMSA 4BType AMSD 4BType AMSABS 3BType AMSABS 4BType AMSA 3LType MINISCALE PLUSType MINISLIDE MSQscale
 MoreMore

More

MoreMoreMoreMoreMoreMore
Magnetoresistiv

  
Optical       
Usable with MONORAIL MR     
Usable with MONORAIL BM      
Usable with MINIRAIL       
Incremental measuring method  
Absolute measurement method       
Usable with MSQ        
  • Legend:
  • 100%100% best choice
  • 75%75%
  • 50%50%
  • 25%25% good choice
  • 0%0%

Product overview AMSD 4B carriages

Technical data and options

Product overview AMSD 4B carriages

Product overview AMSD 4B rails

Technical data and options

Product overview AMSD 4B rails

Downloads

MONORAIL AMSABS 3L - Product brochure
MONORAIL AMSABS 3L - Product brochure Profile linear guideways with absolute measuring system for long axesDownload now
MONORAIL and AMS - Product catalog
MONORAIL and AMS - Product catalog Profile guideways and integrated measuring systemsDownload now
MONORAIL and AMS - Application catalog
MONORAIL and AMS - Application catalog Lubrifiaction, dimensioning, installation, mounting, measure of precautionDownload now
MONORAIL and AMS Mounting instruction
MONORAIL and AMS Mounting instruction Profile guideways and integrated measuring systemsDownload now
RoHS & REACH - Compliance
RoHS & REACH - Compliance SCHNEEBERGER GmbH, Directive 2011/65/EU, Regulation (EC) No 1907/2006, in EnglishDownload now
MONORAIL MR4S - Spare parts and Modification instruction
MONORAIL MR4S - Spare parts and Modification instruction MONORAIL MR4S - Spare parts and Modification instructionDownload now
Mounting notes MONORAIL MR4S
Mounting notes MONORAIL MR4S Mounting notes MONORAIL - Carriages MR4SDownload now
Blue Competence Fyler
Blue Competence Fyler Substainability that pays off.Download now

AMS movie

Our customers' requirements:
A space-saving and quick-to-assemble distance measuring system, which is close to the machining process.

Our solution:
Integrated distance measuring system - high-precision, reliable and low-maintenance.

SCHNEEBERGER overview MONORAIL and AMS

Assembly instructions for SCHNEEBERGER MONORAIL carriages

Assembly instructions for SCHNEEBERGER read heads

Press releases

Integrated measuring system guarantees exact travel distances
Integrated measuring system guarantees exact travel distances For over ten years, Schneeberger has been developing compact, integrated distance measuring systems for its monorail guideways and today, sets the standard in terms of accuracy, design, installation, adjustment, operation and maintenance.Download now
Integrated measuring system for distance measurement
Integrated measuring system for distance measurement Schneeberger offers cost-optimised solutions in the form of its Integrated measuring system for distance measurement, which can be used for a wide range of applications.Download now

CAD data for type AMS measuring system for download:

The selected size can be configured and is available in all common data formats Please click on the appropriate size combination to start downloading. 

By clicking on the following link you will be automatically redirected to CADENAS.

Open CAD data

Advantages

  • Complete sealing of the read head housing including a mechanically robust crosswiper
  • Digital signals direct from the read head without additional interpolation electronics
  • Compact separate box for the sensor electronics
  • Maximum output frequency and hysteresis selectable to customers demand
  • Special reference puls for FANUC controllers

Features

  • Compact read head with separate box for the sensor electronics
  • Transversal mounting direction of the read head
  • Digital interface
  • Accuracy class +/- 5 µm / 1000 mm, +/- 2 µm / 40 mm
  • Periodic deviation +/- 1,0 µm
  • Different resolutions from 0,2 µm - 5,0 µm available
  • Max. speed 3,0 m/s and max. acceleration 30 g
  • Vibration / impacts 30 g

Customer Hotline for integrated measuring system

SCHNEEBERGER Customer Hotline for integrated measuring system

SCHNEEBERGER offers a comprehensive spectrum of services such as repairs, maintenance as well as technical support

  • Languages : German and English
  • In Europe
  • Monday - Friday: 08:00-12:00 / 13:00-16:00
    UTC +1, UTC +2 (March-October) Service

SCHNEEBERGER GmbH
Höfen, Germany

Hotline +49 (0)7081 782 272
Fax        +49 (0)7081 782 124

SCHNEEBERGER E-NEWS
Exclusive advantages for newsletter subscribers:
  • New products and innovations
  • Stay up to date on market trends and developments
  • Information on trade fairs and events
SCHNEEBERGER Newsletter SCHNEEBERGER Newsletter